u  Overview

The BR-10R/RN control is installed in combination with the recloser on MV overhead distribution lines. It is an integrated control device that performs various functions such as status monitoring and measurement of electrical quantities of distribution line, fault detection and line protection, status monitoring of the connected equipment, battery management, and communication for remote control.

 

u  Key Features

     Directional phase and ground overcurrent, negative sequence overcurrent, and SEF protections

     High current trip and lockout

     45 built-in TCC curves, and reclose sequence that can be set up to three reclose

     Four protective setting groups with alternate settings according to power flow direction

     Hot line tag and single shot protection

     Inrush restraint and cold load pickup scheme

     Over/under voltage and frequency protection

     Detection and protection for broken conductors and loss of phase

     Calculation of remaining VI contact life and VT failure detection

     Fault locator, and automatic loop control scheme that does not require communication

       Power quality and line status monitoring, electrical quantity measurement, and status monitoring of related devices in real time

     Battery management and automatic battery test

     Various events and fault waveforms record

     Operating program for setting and verifying parameters, checking status and history data, and downloading firmware

     External indicator to check main conditions from the ground

     Four-digit password security to access the controls

     Drive module to operate the magnetic actuator built into the recloser and two capacitor banks

     DNP3 and IEC 60870-5-101/104 protocol over serial or Ethernet

     Electrically isolated RS 232 and RS 485 ports, and Ethernet portfor connection with distribution automation system

     Status monitoring and remote control via SMS

     Optional GPS and Bluetooth interface

     Auxiliary DI and DO contacts, terminal block, and indicators that can be used according to user‘s purpose

 

u  Applications

     Used as a traditional recloser control installed on distribution lines or in substations to protect distribution lines

     Used as a recloser control to integrate reclosers into distribution automation systems

       Used as a recloser control for lines to which multiple sources are connected, including distributed energy resources

     Used as a recloser control in systems requiring automatic loop control scheme

     Used as a control for the recloser or circuit breaker in systems requiring load shedding to maintain power quality of distribution lines

     Used as a control for the fault interrupters that are installed on customer service lines or branch lines